  Datasheet File OCR Text:
 FMO Series
Mass flow sensors for gases
FEATURES * Ranges 0...25 and 0...1000 sccm1 * Bidirectional sensing * Actual mass flow sensing * Ceramic flow tube * Manifold mount/O-ring sealed * Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with dry gases only. The FMOM025HB is a special sensor for hydrogen (H2) flow. The FMO series is NOT designed for liquid flow and will be damaged by liquid flow through the sensor.
SPECIFICATIONS
Maximum ratings Supply voltage2 8 to 15 V typ. 10 0.01 V max. 60 mW
ELECTRICAL CONNECTION
P1
P2
Power consumption Temperature limits Operating Storage Mechanical shock
-40 to 125C -40 to 125C 100 g (5 drops, 6 axes)
123456
Note: 1 sccm denotes standard cubic centimeters per minute 2 Output voltage is ratiometric to supply voltage
E / 11723 / A
1/6
www.sensortechnics.com
FMO Series
Mass flow sensors for gases
FLOW SENSOR CHARACTERISTICS3
(VS = 10 0.01 V, TA = 25C)
Part no.
FMOM025HB FMOL001DB
Flow range (full scale)
25 sccm 1000 sccm
Max. flow ch an g e4
5.0 l/sec 5.0 l/sec
Output voltage @ trim point
8.5 1.5 mV @ 25 sccm 54.7 3.7 mV @ 1000 sccm
PERFORMANCE CHARACTERISTICS
(VS = 10 0.01 V, TA = 25C)
Characteristics
Zero offset FMOM025HB FMOL001DB Repeatability and hysteresis (combined) Temperature effects5 Offset Span -25 to 85 C -25 to 25 C 25 to 85 C Response time Common mode pressure FMOM025HB FMOL001DB
Min.
-1.0 -1.5
Typ.
0 0
Max.
1.0
Unit
mV
1.5 0.35 % reading 0.50
0.20 2.5
mV % reading
-2.5 1.0 3.0 150 ms p si
Notes: 3 A 5 micron filter is recommended for all devices. 4 Maximum allowable rate of flow change to prevent damage. 5 Shift is relative to 25 C.
E / 11723 / A
2/6
www.sensortechnics.com
FMO Series
Mass flow sensors for gases
FLOW SPECIFICATIONS
(VS = 10 0.01 V, TA = 25C) FMOM025HB
Press. (bar) 20 17 14 10 7 3 0 Flow (sccm)6 30 25 20 15 10 5 0 Nom. (mV) 9.9 8.5 6.8 5.2 3.5 1.7 0.0 Tol. ( mV) 1.5 1.5 1.5 1.0 1.0 1.0 1.0 Press. (mbar) 2.23 1.52 0.94 0.49 0.19 0.00 -0.19 -0.49 -0.94 -1.52 -2.23
FMOL001DB
Flow (sccm)6 1000 800 600 400 200 0 -200 -400 -600 -800 -1000 Nom. (mV) 54.7 53.0 49.3 42.5 29.8 0.0 -29.8 -42.5 -49.3 -53.0 -55.2 Tol. ( mV) 2.0 2.0 2.5 3.5 4.0 1.5 4.0 5.0 6.0 6.0 6.0
Note: 6 Devices are calibrated in mass flow. Tolerance values apply to calibration type only.
OUTPUT VS. FLOW CURVES
FMOM025HB
FMOL001DB
E / 11723 / A
3/6
www.sensortechnics.com
FMO Series
Mass flow sensors for gases
HEATER CONTROL CIRCUIT
SENSING BRIDGE SUPPLY CIRCUIT
Note: These circuits are required for operation per specifications. Circuits are not on board the sensor.
DIFFERENTIAL INSTRUMENTATION AMPLIFIER CIRCUIT (optional)
2 R + R1 R4 (V2 - V1 ) + VOffset VO = 2 R R 1 3 R6 where VOffset = VS R +R 5 6
E / 11723 / A
4/6
www.sensortechnics.com
FMO Series
Mass flow sensors for gases
OUTLINE DRAWING
30.5 (1.20) 27.7 (1.09)
14.0 (0.55) 32.2 (1.19)
7.62 (0.30)
654321
0.64 (0.025)
2.5 (0.10)
34.0 (1.34) 3.0 (0.12) 10.9 8.4 (0.43) (0.33) O 3.0 (O 0.12) O 3.51 (O 0.138) 2.54 (0.10) 7.9 (0.31) 12.7 (0.50)
mass: approx. 14 g third angle projection dimensions in mm (inches)
17.3 (0.68)
4.8 (0.19)
O 6.2 (O 0.24)
P1
P2
O 2.0 (O 0.08)
123456
Note: Positiv flow direction is defined as proceeding from port 1 (P1) to port 2 (P2) and results in positive output (pin 6 > pin 2). Negative flow direction is defined conversely and results in negative output (pin 6 < pin 2).
E / 11723 / A
5/6
www.sensortechnics.com
FMO Series
Mass flow sensors for gases
GAS CORRECTION FACTORS7
Gas type
Helium (He) Hydrogen (H2) Argon (Ar) Nitrogen (N2) Oxygen (O2) Ai r Nitric oxide (NO) Carbon monoxide (CO) Methane (CH4) Ammonia (NH3) Nitrous oxide (N2O) Nitrogen dioxide (NO2) Carbon dioxide (CO2)
Correction factor (approx.)
0.58 0.78,9 0.95 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.35 1.35 1.35
Notes: 7 Gas correction factors are referenced to nitrogen (N2) as calibration gas type. Approximate gas correction factors are provided as guidelines only. Individual gas types may perform differently at temperature extremes and varying flow rates. 8 When sensing Hydrogen (H2) or Helium (He) it may be necessary to power the mass flow sensor using increased supply voltage: Hydrogen typ. 12 V, Helium typ. 15 V 9 Hydrogen (H2) flow measurement requires the use of a special sensor. These devices provide normal operation when sensing hydrogen flow and are designated with an "H" at the end of the order number.
ORDERING INFORMATION - AVAILABLE LISTINGS
Flow range
25 sccm 1000 sccm
Dry gas
FMOL001DB
Hydrogen gas9
FMOM025HB -
Sensortechnics PRO services: * Extended guarantee period of 2 years * Improved performance characteristics * Custom product modifications and adaptations even for small quantities * Advanced logistics models for supply inventory and short delivery times * Technical support through application engineers on the phone or at your site * Fastest possible technical response for design and QA engineers ... plus other services on request
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. E / 11723 / A 6/6
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of FMOL001DB

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X